Search results for "Insulin Infusion Systems"

showing 10 items of 14 documents

The influence of penbutolol and placebo on blood sugar levels and insulin consumption in the glucose-controlled insulin infusion system ("artificial …

1990

The aim of the study was to investigate the influence of 40 mg of the beta-blocker penbutolol (Betapressin TM; Hoechst Ltd., Frankfurt/Main) in comparison to placebo on the insulin consumption on the blood sugar profile in twelve insulin-dependent diabetes (IDDM) patients. The patients were treated with penbutolol and placebo for a period of three days, and then were examined with the help of the glucose-controlled insulin infusion system. The blood sugar profile and insulin consumption over a 24 hour period was not affected by either penbutolol or placebo, nor could any changes be measured in these parameters when measured after food intake. After a submaximal exercise load on the bicycle …

AdultBlood GlucoseMalemedicine.medical_specialtyAdolescentmedicine.drug_classmedicine.medical_treatmentBlood sugarPhysical exercisePlaceboPlacebosCatecholaminesInsulin Infusion SystemsPenbutololDiabetes mellitusInternal medicineDrug DiscoverymedicineHumansInsulinBeta blockerExerciseGenetics (clinical)Artificial endocrine pancreasbusiness.industryInsulinGeneral Medicinemedicine.diseaseHormonesEndocrinologyDiabetes Mellitus Type 1Molecular MedicineFemalePenbutololbusinessmedicine.drugKlinische Wochenschrift
researchProduct

Impact of physical exercise on sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system in people with Ty…

2019

AIMS To evaluate the sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system using reference blood glucose levels during moderate-intensity exercise while on either full or reduced basal insulin dose in people with Type 1 diabetes. METHODS Ten participants with Type 1 diabetes [four women, mean ± sd age 31.4 ± 9.0 years, BMI 25.5±3.8 kg/m2 , HbA1c 55±7 mmol/mol (7.2±0.6%)] exercised on a cycle ergometer for 55 min at a moderate intensity for 5 consecutive days at the clinical research facility, while receiving either their usual or a 75% basal insulin dose. After a 4-week washout period, participants performed the second exercise period having sw…

AdultBlood GlucoseMalemedicine.medical_specialtyEndocrinology Diabetes and Metabolism030209 endocrinology & metabolismPhysical exerciseBiosensing Techniques03 medical and health sciencesYoung Adult0302 clinical medicineEndocrinologyInsulin Infusion SystemsInterquartile rangePredictive Value of TestsDiabetes mellitusInternal medicineInternal MedicinemedicineHumansInsulin030212 general & internal medicineExercise physiologyBlood Glucose MeasurementExerciseType 1 diabetesCross-Over StudiesDose-Response Relationship Drugbusiness.industryBlood Glucose Self-MonitoringEquipment Designmedicine.diseaseCrossover studyDiabetes Mellitus Type 1Equipment and SuppliesPredictive value of testsCardiologyFemalebusiness
researchProduct

No change in apolipoprotein AI metabolism when subcutaneous insulin infusion is replaced by intraperitoneal insulin infusion in type 1 diabetic patie…

2006

In type 1 diabetic patients, the replacement of subcutaneous insulin infusion by intraperitoneal insulin infusion restores the normal physiological gradient between the portal vein and the peripheral circulation, which is likely to modify HDL metabolism. This stable isotope kinetic study was designed to compare HDL apolipoprotein (apo) AI metabolism in seven type 1 diabetic patients first treated by continuous subcutaneous insulin infusion by an external pump and then 3 months after the beginning of intraperitoneal insulin infusion by an implantable pump. Glycaemic control was comparable under subcutaneous and intraperitoneal insulin infusion (HbA1c=7.34+/-0.94% versus 7.24+/-1.00%, NS). HD…

AdultMalemedicine.medical_specialtyApolipoprotein Bmedicine.medical_treatmentCarbon Compounds InorganicSulfidesAdministration Cutaneouschemistry.chemical_compoundInsulin Infusion SystemsDiabetes mellitusInternal medicinemedicineHumansInsulinInfusions ParenteralPancreatic hormoneType 1 diabetesTriglyceridebiologyApolipoprotein A-Ibusiness.industryCholesterolInsulinMetabolismMiddle Agedmedicine.diseaseKineticsEndocrinologyDiabetes Mellitus Type 1chemistrybiology.proteinFemaleCardiology and Cardiovascular MedicinebusinessLipoproteins HDLAtherosclerosis
researchProduct

Extensive Assessment of Blood Glucose Monitoring During Postprandial Period and Its Impact on Closed-Loop Performance.

2017

[EN] Background: Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances in blood glucose control, and postprandial period (PP) is a challenging situation for both CL system and CGM accuracy. Methods: We performed an extensive analysis of sensor¿s performance by numerical accuracy and precision during PP, as well as its influence in blood glucose control under CL therapy. Results: During PP the mean absolute relative difference (MARD) for both sensors presented lower accuracy in the hypoglycemic range (19.4 ± 12.8%) than in other ranges (12.2…

Blood GlucoseMaleTime FactorsGlucose controlEndocrinology Diabetes and MetabolismSpecial Section: Artificial Pancreas: Models Signals and Control0302 clinical medicineInsulin030212 general & internal medicineContinuous glucose monitoringAccuracymedicine.diagnostic_testContinuous glucose monitoringPostprandial periodSignal Processing Computer-AssistedMiddle AgedPostprandial PeriodINGENIERIA DE SISTEMAS Y AUTOMATICAType 1 diabetesPostprandialTreatment OutcomeClosed-loop controlCardiologyFemaleGlucose monitorsAlgorithmsAdultmedicine.medical_specialtyTransducersBiomedical Engineering030209 endocrinology & metabolismBioengineering03 medical and health sciencesInsulin Infusion SystemsPredictive Value of TestsInternal medicineInternal MedicinemedicineHumansHypoglycemic AgentsBlood glucose monitoringType 1 diabetesbusiness.industryBlood Glucose Self-MonitoringReproducibility of Resultsmedicine.diseaseHypoglycemiaEndocrinologyDiabetes Mellitus Type 1businessClosed loopBiomarkersJournal of diabetes science and technology
researchProduct

Psychosocial aspects of diabetes technology

2020

Aim To identify key psychosocial research in the domain of diabetes technology. Results Four trajectories of psychosocial diabetes technology research are identified that characterize research over the past 25 years. Key evidence is reviewed on psychosocial outcomes of technology use as well as psychosocial barriers and facilitating conditions of diabetes technology uptake. Psychosocial interventions that address modifiable barriers and psychosocial factors have proven to be effective in improving glycaemic and self-reported outcomes in diabetes technology users. Conclusions Psychosocial diabetes technology research is essential for designing interventions and education programmes targeting…

GerontologyTechnology researchEndocrinology Diabetes and MetabolismMEDLINEPsychological interventionInsulin delivery030209 endocrinology & metabolismHistory 21st Century03 medical and health sciences0302 clinical medicineEndocrinologyInsulin Infusion SystemsInventionsDiabetes mellitusInternal MedicinemedicineDiabetes MellitusHumansInsulinPsychology030212 general & internal medicinebusiness.industryDiabetes mellitus therapyHistory 20th Centurymedicine.diseaseEquipment and Supplies150 PsychologieRelated researchbusiness150 PsychologyPsychosocialBehavioral SciencesDelivery of Health Care
researchProduct

Continuous glucose monitoring use and glucose variability in very young children with type 1 diabetes (VibRate): A multinational prospective observat…

2021

While data on the efficacy and safety of continuous glucose monitoring (CGM) exist across a broad age spectrum, it is limited in very young children with type 1 diabetes (T1D). We aimed to assess real-world data in this high-risk population, focusing on glycemic variability and metrics beyond HbA1c. A 12-month multi-national, prospective, observational, registry-based cohort study in children with T1D aged 1-7 years compared glucose control using real-time CGM and using fingerstick blood glucose monitoring (BGM) alone. The prespecified primary endpoint was a difference in coefficient of variation (CV) between the CGM users and BGM-only cohort. Among 227 individuals using insulin pumps (42% …

Insulin pumpBlood GlucosePediatricsmedicine.medical_specialtyendocrine system diseasesFingerstickEndocrinology Diabetes and MetabolismPopulationChildren; Continuous glucose monitoring; Insulin pump; Toddlers; Type 1 diabetesCohort StudiesHDE END PEDEndocrinologyInsulin Infusion SystemsInternal MedicinemedicineHumansHypoglycemic AgentsInsulinInsulin pumpeducationChildChildrenContinuous glucose monitoringchildren; continuous glucose monitoring; insulin pump; toddlers; type 1 diabetesGlycemicBlood glucose monitoringGlycated HemoglobinToddlerseducation.field_of_studyType 1 diabetesmedicine.diagnostic_testEndocrinology; Metabolismbusiness.industryBlood Glucose Self-Monitoringnutritional and metabolic diseasesDiabetes type 1medicine.diseaseType 1 diabetesDiabetes Mellitus Type 1GlucoseChild PreschoolCohortbusinessCohort studyDiabetes Obesity & Metabolism
researchProduct

Glycemic Outcome Associated With Insulin Pump and Glucose Sensor Use in Children and Adolescents With Type 1 Diabetes. Data From the International Pe…

2021

OBJECTIVE Insulin delivery methods, glucose-monitoring modalities, and related outcomes were examined in a large, international, diverse cohort of children and adolescents with type 1 diabetes from the Better Control in Pediatric and Adolescent Diabetes: Working to Create Centers of Reference (SWEET) -Registry. RESEARCH DESIGN AND METHODS Participants with type 1 diabetes of >= 1 year, aged <= 18 years, and who had documented pump or sensor usage during the period August 2017-July 2019 were stratified into four categories: injections-no sensor (referent); injections + sensor; pump-no sensor; and pump + sensor. HbA(1c) and proportion of patients with diabetic ketoacidosis (DKA) or severe hyp…

Insulin pumpKetoacidosisBlood Glucosemedicine.medical_specialtyDiabetic ketoacidosisAdolescentEndocrinology Diabetes and MetabolismDpv030209 endocrinology & metabolismHypoglycemia03 medical and health sciences0302 clinical medicineInsulin Infusion SystemsDiabetes mellitusInternal medicineInternal MedicinemedicineHumansHypoglycemic AgentsInsulin030212 general & internal medicineRegistriesChildGlycemicAdvanced and Specialized NursingGlycated HemoglobinType 1 diabetesbusiness.industryBlood Glucose Self-Monitoringmedicine.diseaseQualityHypoglycemiaKetoacidosisDiabetes Mellitus Type 1CohortTherapybusinessDiabetes Care
researchProduct

Body mass index, basal insulin and glycemic control in children with type 1 diabetes treated with the advanced hybrid closed loop system remain stabl…

2022

BackgroundInformation on the influence of insulin treatment using advanced hybrid closed loop systems (AHCL) on body weight of young patients with type 1 diabetes (T1D) is scarce. The aim of this study was to observe whether there were any changes in body mass index (BMI) of children and adolescents with T1D treated using the Medtronic Minimed 780G AHCL after 1 year of follow up and to analyze potential associations between these changes and the insulin doses.Materials and methodsFor 50 children and adolescents (age 5.4-16.8 years, 24 (48%) boys, T1D for 3.9 ± 2.56 years) using an AHCL system anthropometric and AHCL data were collected prospectively. BMI Z-scores and two-week AHCL records o…

MaleBlood GlucoseAdolescenttype 1 diabetesEndocrinology Diabetes and MetabolismBody WeightGlycemic Controladvanced hybrid closed-loop systemBody Mass IndexBMIDiabetes Mellitus Type 1Insulin Infusion SystemsGlucosechildrenChild Preschooltime in rangetotal daily insulin doseHumansHypoglycemic AgentsInsulinFemalebasal insulinProspective StudiesChildFrontiers in endocrinology
researchProduct

Glycaemic control of Type 1 diabetes in clinical practice early in the 21st century: an international comparison

2015

AimsImproving glycaemic control in people with Type1 diabetes is known to reduce complications. Our aim was to compare glycaemic control among people with Type1 diabetes using data gathered in regional or national registries. MethodsData were obtained for children and/or adults with Type1 diabetes from the following countries (or regions): Western Australia, Austria, Denmark, England, Champagne-Ardenne (France), Germany, Epirus, Thessaly and Thessaloniki (Greece), Galway (Ireland), several Italian regions, Latvia, Rotterdam (The Netherlands), Otago (New Zealand), Norway, Northern Ireland, Scotland, Sweden, Volyn (Ukraine), USA and Wales) from population or clinic-based registries. The sampl…

MaleDenmarkEndocrinology Diabetes and Metabolismmetabolic-controlregistryEndocrinologyGermanyInsulinMedicineadolescentsRegistriesYoung adultNetherlandseducation.field_of_studyGreeceNorway18 countriesClinical PracticeEnglandItalyAustriaPractice Guidelines as TopicFemaleFranceGuideline AdherenceUkraineAdultcomplicationsAdolescentPopulationNorthern IrelandNorthern irelandAge and sexYoung AdultInsulin Infusion SystemschildrenDiabetes mellitusInternal MedicineHumansHypoglycemic AgentscareeducationchildhoodGlycated HemoglobinSwedenType 1 diabetesWalesbusiness.industryWestern Australiamedicine.diseaseLatviaiddmUnited StatesDiabetes Mellitus Type 1ScotlandSample size determinationOptometrybusinessIrelandNew ZealandDemographyDiabetic Medicine
researchProduct

The automated pancreas: A review of technologies and clinical practice

2021

Insulin pumps and glucose sensors are effective in improving diabetes therapy and reducing acute complications. The combination of both devices using an algorithm-driven interoperable controller makes automated insulin delivery (AID) systems possible. Many AID systems have been tested in clinical trials and have proven safety and effectiveness. However, currently, none of these systems are available for routine use in children younger than 6 years in Europe. For continued use, both users and prescribers must have sound knowledge of the features of the individual AID systems. Presently, all systems require various user interactions (e.g. meal announcements) because fully automated systems ar…

Pancreas ArtificialInsulin pumpTelemedicinebusiness.industryBlood Glucose Self-MonitoringEndocrinology Diabetes and MetabolismInteroperabilityHCL; artificial pancreas; automated delivery; closed loop; insulin; insulin AIDCloud computingDiabetes TherapyArtificial pancreasClinical trialInsulin Infusion SystemsEndocrinologyRisk analysis (engineering)Diabetes MellitusInternal MedicineHumansMedicineMetric (unit)ChildbusinessDiabetes, Obesity and Metabolism
researchProduct